BTEX Condenser Unit
TankSafe's patented vapour recovery assembly provides an effective, economical and
environmentally responsible means for BTEX emission reduction, saleable condensate
collection, odour control and visual plume curtailment at glycol dehydration facilities.
The integral combination of TankSafe's heated Storage Tank with a roof mounted condenser
is an industry proven product that has been tested extensively by third party laboratories
since 1998. This testing has consistently demonstrated the following average results:
- Benzene emission reduction efficiency of 90%
- Total BTEX emission reduction efficiency of 93%
- Total liquid recovery efficiency of 99.7%
- Total liquid recovery of 1.3 BBL/day (avg. 40% of which is saleable condensate)
- Total flow (total emitted volume) reduction of approximately 60-70%
The BTEX Condenser unit successfully reduces air pollution by simply taking advantage of
ambient air temperature conditions in combination with the condensing unit's excessive
vapour retention time and surface contact area. All liquids are stored and contained
within TankSafe's integrated patented Storage Tank with 110% secondary containment. The
process does not require any seasonal adjustments and, except for selected level gauge,
BTEX Condenser units do not contain any moving parts.